If error message “CPU Not OK” is output, all contacts
open.
n
Control
Number : 5
Base card : 3
Option card : 2
Type : 24 V(DC) +/-30 %, 5 mA,
galvanically isolated
n
Control inputs (NAMUR)
Number : 2
Type : NAMUR (DIN 19234),
short-circuit and cable
breakage monitoring
n
Analog output
Number : 2
Base card : 1
Option card : 1
Current : raise ...20 mA impressed
Raise : 0... <20 mA
Load : max. 500 ohms
Reference : 0 V by user,
galvanically isolated
Resolution :
12 bits +/- 1 d
If error message “CPU Not OK” is output, output
signal turn 0 mA.
n
Analog input
Number : 1
Current : raise ...20 mA impressed
Raise : 0... 20 mA
Load : 500 ohms
Reference : 0 V internal,
galvanically non isolated
Resolution : 10 bits +/- 1/2 d
Acuracy : <0.4% over entire
temperature range
n
External totalizing pulse counter
Frequency : max. 10 Hz
Pulse length : selectable 50...1000 ms
Output : 24 V, max. 100 mA
optionally active low or active
high,
galvanically isolated,
short-circuit-proof, limited to
apr. 350 mA,
negative amounts are stored
internally and must be
compensated by positive
amounts before new pulse is
output.
This ensures integral
accuracy also with minimal
belt load.
n
Serial printer interface
Number : 1 (option card)
Type : RS 232 (V24), max. 38400
baud
Data format : 8 data bits, 1 stop bit, no
parity
Isolation : galvanically non-isolated
Connectors : Phoenix MSTB, contat
spacing 3.5 mm, max.
1.5 mm
2
Character map : ISO-Latin-1 (ISO-8859-1)
n
Load cell connection
Voltage supply : +/-6VAC(+/-3 %)
(apr. 66 Hz
short-circuit-proof
Measuring cycle : 100ms
Resolution : 24 Bit
Load : R (load cell) = min. 80 ohms
Cable length : max. 30 % voltage drop,
max. 500 m
Measuring range : -20mV....+50mV
with VLW:
-1.6mV...min. 32mV
0837
VBW INTECONT PLUS
Technical Data
BV-H2214 GB 26
Technische
Redaktion PDE-RD
Transmission to third parties and reproduction of
this documentation are not permitted. Schenck
Process GmbH reserves all rights of ownership
and copyrights.