Block V: Fixmode Parameters
As of version VBW20600-08, the options FIXED-1 and
FIXED-2 in parameter L06, “Configuration”, are no
longer available and have been replaced by
FIXED.The values carried over with the setting FIXED
are determined by the following parameters. The
settings of the original values correspond to the
previous FIXED mode 1.A list of all available
identifiers and FIXED mode examples can be found in
the manual BV-H2220.
V01 ID preset value 1
Range: Fest eingestellt Default: 320
Command 4+5
V02 ID preset value 2
Range: 0...4086 Default: 352
Command 6+7
V03 ID preset value 3
Range: 0...4086 Default: 384
Command 8+9
V04 ID preset value 4
Range: 0...4086 Default: 596
Rreload setpoint [kg]
V05 ID preset value 5
Range: 0...4086 Default: 594
Batch setpoint [kg]
V06 ID preset value 6
Range: 0...4086 Default: 598
Batch number
V07 ID preset value 7
Range: 0...4086 Default: 0
V08 ID preset value 8
Range: 0...4086 Default: 0
V09 ID read value 1
Range: 0...4086 Default: 752
Status 2+3
V10 ID read value 2
Range: 0...4086 Default: 784
Status 4+5
V11 ID read value 3
Range: 0...4086 Default: 1552
Highest priority event
V12 ID read value 4
Range: 0...4086 Default: 1872
Actual flow rate [kg/hr]
V13 ID read value 5
Range: 0...4086 Default: 1874
Totalizing counter 1 [kg]