The following parameters are defined for each tuning entry:
ISDB-T Tuning setup Edit:
Name: A name should be assigned to each tuning configuration.
Frequency: The channel center frequency in MHz.
Channel spacing: The channel spacing in MHz
ETR thresholds:
Selection of the ETR threshold template that should be assigned to the current
frequency
PID thresholds:
Selection of the PID threshold template that should be assigned to the current
frequency
Service thresholds:
Selection of the Service threshold template that should be assigned to the
current frequency
Reference table set:
The Reference table set selection is used to compare the tables in the trans-
port stream with a set of stored tables. These tables are defined in the
ETR
290 Gold TS thresholds view.
ISDB-T thresholds:
Selection of the ISDB-T threshold template that should be assigned to the
current frequency
VBC thresholds:
Selection of the VBC threshold template that should be assigned to the current
frequency
Extract thumbnails:
When enabled, the probe will generate thumbnails for this tuning whenever
tuned to it. If not, they can be generated manually by opening the thumbnail
pop-up from the
Main Thumb overview
and
ETR 290 Services
views.