6.3.5 OTT Settings
The Settings tab makes it possible to change OTT global monitoring parameters. Press
Apply
to confirm
changes made.
Settings
Round time:
Sets the minimum round time of all of the OTT engines, in seconds (default:
15 seconds). If an engine finishes processing all its channels in less time
than this, it waits until this amount of seconds has passed since it started
the round before starting to process through its channels again.
Note: The round time may not be set to any value less than 2 second.
Reset connection after:
Configures the VB220 OTT engines to reset the connections after the
specified number of minutes. This is useful for cases where the server
has a limit for how long a session can live. By resetting before that limit a
new session is created and the problem is avoided.
Latency engines:
Select the number of engines to dedicate to OTT latency monitoring.
These engines will not be available for regular OTT monitoring, and the
value must be less than the total number of licensed OTT engines on the
probe (up to 25 for the VB220). See OTT Latency for more info.
6.3.6 OTT Thresholds
The OTT Threshold presets list shows OTT threshold templates configured by the user.
VB2xx GigE User’s Manual version 5.4 77

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sencore VB2 Series and is the answer not in the manual?

Sencore VB2 Series Specifications

General IconGeneral
BrandSencore
ModelVB2 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals