Overview of power section parameters
Parameters
Unit functions
Index Parameter name MOVITOOLS
®
MotionStudio
Display
(Range / factory setting)
MOVILINK
®
scaling
Power section parameters \ unit functions \ setup
8594.0 Factory setting • 0 = No
• 1 = Standard
• 2 = Delivery status
• 3 = Basic initialization
8595.0 Parameter lock • 0 = No
•1 = Yes
Power section parameters \ unit functions \ error monitoring
Programmable responses
9729.16 Response ext. error • 0 = No response
• 1 = Display only
• 2 = Output stage inhibit / locked
• 3 = Emergency stop / locked
• 4 = Stop / locked
• 5 = Output stage inhibit / waiting
• 6 = Emergency stop / waiting
• 7 = Stop / waiting
9729.4 Line phase failure response • 0 = No response
• 1 = Display only
• 2 = Output stage inhibit / locked
• 3 = Emergency stop / locked
• 4 = Stop / locked
• 5 = Output stage inhibit / waiting
• 6 = Emergency stop / waiting
• 7 = Stop / waiting
9729.9 TF signal response • 0 = No response
• 1 = Display only
• 2 = Output stage inhibit / locked
• 3 = Emergency stop / locked
• 4 = Stop / locked
• 5 = Output stage inhibit / waiting
• 6 = Emergency stop / waiting
• 7 = Stop / waiting
8615.0 Only in connection with DSC (D
irect SBus
I
nstallation) unit variant:
Response SBus 1 timeout
• 0 = No response
• 1 = Display only
• 2 = Output stage inhibit / locked
• 3 = Emergency stop / locked
• 4 = Stop / locked
• 5 = Output stage inhibit / waiting
• 6 = Emergency stop / waiting
• 7 = Stop / waiting
Error acknowledgement
8617.0 Manual reset • 0 = No
•1 = Yes
Power section parameters \ unit functions \ scaling of actual speed value
8747.0 Scaling factor for user display numerator 1 – 65535
8748.0 Scaling factor for user display denominator 1
– 65535
8772.0 User unit [Text]