Operating Instructions – Electronic Motor DRC.-..-SNI
107
8
Description of command PCB parameters
Parameters
Command pcb parameters \ display values \ unit data
Unit series The parameter indicates the unit series, for example DRC.
Unit name
index 9701.1 –
9701.5
The parameter indicates the type designation of the command PCB.
Unit signature
index 9823.1 –
9823.5
The parameter is used to indicate and enter the device signature. This parameter is
used to assign a name to the command PCB so you can identify it in the hardware tree
or in other visualization elements.
Firmware
command level
index 9701.30,
9701.31
The parameter indicates the part number of the firmware used in the command PCB.
Firmware SNI
interface
index 9701.36,
9701.37
The parameter indicates the program version of the firmware used for SNI communica-
tion.
Application option
type index 10453.1
The parameter indicates the designation of the application option inserted in the appli-
cation slot.
Command PCB parameters \ display values \ address settings
MAC address
index 8995.0 –
8996.0
The parameter indicates the MAC address of the DRC SNI drive unit.