108
Operating Instructions – Electronic Motor DRC.-..-SNI
8
Description of command PCB parameters
Parameters
8.4.2 Setpoints/ramp generators
Command PCB parameters \ setpoints/ramp generators \ setpoints
Setpoint n_f1
index 10096.35
Use this parameter to set setpoint "n_f1".
Unit: [rpm]
Setting range: 0 – 1500
2000 rpm
The setpoint "n_f1" is valid if
local mode is active (DIP switch S2/3 = "1") and a "0" signal is present at binary input
DI03 "f1/f2".
Setpoint n_f2
index 10096.36
Use this parameter to set setpoint "n_f2".
Unit: [rpm]
Setting range: 0 – 200
2000 rpm
The setpoint n_f2 is valid if
local mode is active (DIP switch S2/3 = "1") and a "1" signal is present at binary input
DI03 "f1/f2".
8.4.3 Unit functions
Command pcb parameters \ unit functions \ setup
Factory setting
index 8594.0
Parameter 8594.0 is used to reset the factory settings stored in the EEPROM for almost
all parameters.
Setting range:
•0 = No
1 = Standard
2 = Delivery status
3 = Basic initialization
The following data is not reset when "standard" is selected:
IPOS program
Speed task 1 / 2
The "delivery state" setting also resets the data listed above.
Once the data has been reset, parameter 8594.0 automatically reverts to "NO".