Description of power section parameters
Parameters
Binary inputs
DI00–DI04 t-0–4
index 8371.0,
8372.0, 8373.0,
8374.0, 8375.0 bits
0–4
The parameter indicates the state of the binary inputs at the time of the error.
Binary inputs
DI10–DI17 t-0–4
index 8376.0,
8377.0, 8378.0,
8379.0, 8380.0 bits
0–7
The parameter indicates the state of the binary inputs at the time of the error.
Binary outputs
DO10–DO17
t-0–4 index
8386.0, 8387.0,
8388.0, 8389.0,
8390.0 bits 0 – 7
The parameter indicates the state of the binary outputs at the time of the error.
Actual speed
t-0–4
index 8401.0,
8402.0, 8403.0,
8404.0, 8405.0
The parameter indicates the actual motor speed at the time of the error.
• Unit [rpm]
Apparent output
current t-0–4
index 8406.0,
8407.0, 8408.0,
8409.0, 8410.0
The parameter indicates the apparent output current in percent of the nominal unit
current at the time of the error.
•Unit [%]
Active output
current t-0–4
index 8411.0,
8412.0, 8413.0,
8414.0, 8415.0
The parameter indicates the active output current in percent of the nominal unit current
at the time of the error.
•Unit [%]
Unit utilization
t-0–4
index 8414.0,
8417.0, 8418.0,
8419.0, 8420.0
The parameter indicates the unit utilization Ixt at the time of the error.
• Unit: [%]
Motor utilization
t-0–4
index 8441.0,
8442.0, 8443.0,
8444.0, 8445.0
The parameter indicates the motor utilization calculated using the motor model and the
current at the time of the error.
• Unit: [%]