Operating Instructions – Electronic Motor DRC.-..-SNI
131
8
Description of power section parameters
Parameters
Speed setpoint /
actual value
comparison
Signal if the speed is equal to or not equal to the setpoint speed.
Hysteresis
index 8547.0
Setting range: 1 – 100
– 300 rpm
Delay time index
8548.0
Setting range: 0 – 1
– 9 s
Signal = "1" if:
Index 8549.0
Setting range: n = n
setpt
/ n <> n
setpt
9007202042193547
t
1
1
0
0
Index 8548.0
t
t
Index 8547.0
n rpm
n
set
Signal = "1" if n = n
set
Index 8549.0:
Index 8549.0:
Signal = "1" if n <> n
set