Prerequisites
•
Exis
ting connection between Safety Designer and device
•
Configuration in the project and configuration in the device are synchronized.
11.4.2 Event history
Overview
Figure 52: Event history
1
Data source
2
Available views
3
Navigation
The safety laser scanner stores data on important events. The event history displays
inf
ormation about the most recently stored events.
Event memory in the safety laser scanner
T
he safety laser scanner stores data on the following events:
•
Safety output switches to the OFF state.
•
The protective field, the reference contour field or the contour identification field is
interrupted.
For each field interruption where a safety output switches to the OFF state, the safety
laser scanner stores the data from 10 scans. When the internal memory of the safety
laser scanner is full, the scan data of the oldest field interruption is overwritten to store
a new field interruption. The position and time of the field interruption are retained.
The internal memory of the safety laser scanner is emptied when it is restarted.
TROUBLESHOOTING 11
8024596/15VP/2019-11-15 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O
107
Subject to change without notice