13 Technical data
13.1 Version numbers and functional scope
Functional scope
Older de
vices might not support the full functional scope of the latest Safety Designer.
To identify the different levels of the functionality, we use a three-digit version number.
The functional scope of the device is at the following locations:
•
Type label, Version field
•
Display, entry in the Hardware menu
•
Safety Designer, Overview dialog box (only with connected devices)
•
Safety Designer, report
Table 27: Functional scope
Type code Version number Amendments and new functions
NANS3-AAAZ30AN1 1.0.0
•
F
irst released version
NANS3-CAAZ30AN1 1.0.0
•
First released version
Revision
To identify the different revision levels of the devices, we use a three-digit version num‐
ber. The revision level of the device is indicated on the type label in the Revision field.
Table 28: Revision
Type code Version number Amendments and new functions
NANS3-AAAZ30AN1 1.0.0
•
F
irst released version
NANS3-CAAZ30AN1 1.0.0
•
First released version
13.2 Data sheet
13.2.1 nanoScan3 I/O
Table 29: Features
nanoScan3 Core I/O nanoScan3 Pro I/O
Protective field range ≤ 3.0 m, details: see "Sensin
g range", page 117
Scanning range of the refer‐
ence contour field
Like protective field range, see "Sensing range", page 117
Scanning range of the con‐
t
our detection field
Like protective field range, see "Sensing range", page 117
Warning field range ≤ 10 m
Distance measurement range ≤ 40 m
Fields ≤ 8 ≤ 128
Simultaneously monitored
f
ields
≤ 4 ≤ 8
Field sets ≤ 8 ≤ 128
Monitoring case tables 1 2
Monitoring cases ≤ 2 ≤ 128
Scanning angle 275° (–47.5° to 227.5°)
Protective field resolution 20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 70 mm, 150 mm,
200 mm
Angular resolution 0.17° mm
TECHNICAL DATA 13
8024596/15VP/2019-11-15 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O
111