7.18.1 Device restart
If you have problems with the device, you can restart the device or subsections of the
de
vice (safety function, connections, additional functions).
Restarting safety function
•
The fastest type of restart
•
Serious faults remain, even if the cause has been rectified (for example a locking
state because of a supply voltage which is too low).
•
Communication with the device remains intact (connections for configuration,
safety function and data not relating to safety).
•
Communication beyond the device is not impaired.
Restarting safety function and connections
•
The device’s function is also re-established after serious faults if the cause has
been rectified.
•
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety). The device sets up communication
again automatically after restarting.
•
Communication beyond the device is not impaired.
Restarting device completely
•
The device behaves exactly as it does when the voltage supply is switched off and
back on again.
•
The device’s function is also re-established after serious faults if the cause has
been rectified.
•
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety).
•
Communication beyond the device is interrupted. This may also affect devices
which communicate beyond the device.
7.18.2 Factory settings
Before reconfiguring the device, you can reset all settings to factory settings.
Resetting safety function to factory settings
•
T
he configuration for the safety function is reset to factory settings.
•
Communication beyond the device is not impaired.
Resetting the safety function and communication settings to factory defaults
•
The configuration for the safety function is reset to factory settings.
•
The configuration of device communication is reset to factory settings (connec‐
tions for configuration, safety function and data not relating to safety).
Resetting whole device to factory settings
•
The configuration for the safety function is reset to factory settings.
•
The configuration of device communication is reset to factory settings (connec‐
tions for configuration, safety function and data not relating to safety).
•
The Maintenance and Authorized customer user groups are deactivated.
•
The password of the Admin user group is reset to the factory settings.
7 C
ONFIGURATION
86
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O 8024596/15VP/2019-11-15 | SICK
Subject to change without notice