Status indicator
T
able 23: Overview of status information
Display Device or configura‐
t
ion
Meaning
All devices and config‐
ur
ations
All fields clear, safety outputs in ON state.
The number at bottom right indicates the
active monitoring case.
Devices and configu‐
rations with a config‐
ured safety output
Protective field interrupted, safety output in
OFF state.
Devices and configu‐
r
ations with 2 config‐
ured safety outputs
For the cut-off paths of both safety outputs,
the following applies: the protective field is
interrupted or there is a warning field in the
active monitoring case. Safety outputs in the
OFF state.
Each column stands for a safety output.
Devices and configu‐
r
ations with 2 config‐
ured safety outputs
The protective field in the cut-off path of safety
output 1 is interrupted or there is a warning
field in the active monitoring case. The safety
output is in the OFF state.
Safety outputs for which no field is interrupted
and which are in the ON state are marked with
their number.
Devices with 2 safety
out
puts if only safety
output 2 is configured
The protective field in the cut-off path of safety
output 2 is interrupted or there is a warning
field in the active monitoring case. The safety
output is in the OFF state.
Safety outputs that are not configured are not
marked.
Configuration with
r
estart interlock
Protective field is clear, reset can take place.
Configuration with
restart interlock
Reset button pressed. Safety output in the OFF
state.
Configuration with
r
estart interlock
Reset button pressed. Safety output in the ON
state.
Configuration with
aut
omated restart
after a time
Protective field is clear, configured time to
restart expires.
Configuration with at
le
ast one warning field
Warning field interrupted (left column: number
of interrupted warning fields, right col‐
umn: number of warning fields in the current
monitoring case).
OPERATION 9
8024596/15VP/2019-11-15 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O
93
Subject to change without notice