nanoScan3 Core I/O nanoScan3 Pro I/O
Height above sea level during
opera
tion
≤ 2,300 m
Vibration resistance
5)
Standards
•
IE
C 60068-2-6
•
IEC 60068-2-64
•
IEC 60721-3-5
•
IEC TR 60721-4-5
•
IEC 61496-3
Class 5M1 (IEC 60721-3-5)
Sinusoidal vibrations
•
0.35 mm, 50 m/s², 10 Hz … 150 Hz
•
1.5 mm, 1 Hz … 9 Hz
•
50 m/s², 9 Hz … 200 Hz
•
10 m/s², 10 Hz … 1,000 Hz
Noise vibrations
•
0.3 m²/s³, 10 Hz … 200 Hz
•
0.1 m²/s³, 200 Hz … 500 Hz
•
50 m/s², 10 Hz … 500 Hz
Shock resistance
5)
Standards
•
IE
C 60068-2-27
•
IEC 60721-3-5
•
IEC TR 60721-4-5
•
IEC 61496-3
Class 5M1 (IEC 60721-3-5)
Single shock 150 m/s², 11 ms
Continuous shock
•
50 m/s², 11 ms
•
100 m/s², 16 ms
EMC In accordance with IEC 61496-1, IEC 61000-6-2, and
IE
C 61000-6-3
1)
The specified enclosure rating only applies if the optics cover and the system plug are mounted and the
U
SB connection is closed with the protective cover.
2)
For ambient light sources directly in the scan plane in accordance with IEC 61496-3: ≤ 3 klx
3)
IEC 61496-1, no. 4.3.1 and no. 5.4.2, IEC 61496-3, no. 4.3.1 and no. 5.4.2. Condensation has an influ‐
ence on normal operation.
4)
IEC 61496-1, no. 4.3.1 and no. 5.4.2, IEC 61496-3, no. 4.3.1 and no. 5.4.2. Condensation has an influ‐
ence on normal operation.
5)
In direct mounting.
Table 35: Miscellaneous data
nanoScan3 Core I/O nanoScan3 Pro I/O
Type of light Pulsed laser diode
Wavelength 905 nm
Detectable reflectance factor 1.8% to several 1,000%
Maximum uniform contami‐
na
tion of the optics cover
without reducing the detec‐
tion capability
1)
30%
Area where detection capabil‐
ity is restricted
≤ 50 mm
2)
Light spot size
At front screen 9 mm × 3 mm
At 3.0 m distance 15 mm × 2 mm
TECHNICAL DATA 13
8024596/15VP/2019-11-15 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O
115
Subject to change without notice