Drawing a reference contour field
1.
Select the tool for drawing reference contour fields.
2. First, use the mouse to click the desired contour.
3. Click to add the corners of the contour.
4. Finally, double-click the contour.
✓
The reference contour field is displayed.
Multiple sampling and object resolution
At first, the object resolution and multiple sampling configured for the monitoring plane
apply for all fields. If necessary, you can make changes to each individually at a later
date.
Tolerance band
A contour has a positive and a negative tolerance band. The cut-off path goes to the
OFF state if the safety laser scanner does not detect the contour inside the tolerance
band.
•
Positive tolerance (remote): the tolerance away from the safety laser scanner
•
Negative tolerance (near): the tolerance towards the safety laser scanner
7.10 Fields
Overview
Figure 41: Field editor
1
Toolbar
7 CONFIGURATION
66
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O 8024596/15VP/2019-11-15 | SICK
Subject to change without notice