In many cases, a mounting height of 150 mm above the floor (height of the scan plane)
is suit
able.
Figure 25: Recommended fitting height
Figure 26: Recommended fitting height for inverted mounting
4.4 Integrating the equipment into the electrical control
Requirements for use
•
T
he control of the machine can be electrically influenced.
•
The connected controller and all devices responsible for safety comply with the
required performance level and the required category (for example according to
ISO 13849-1).
•
Power is supplied to all electrically connected devices in accordance with SELV/
PELV (IEC 60204-1).
•
All electrically connected devices are supplied from the same power supply.
4 P
ROJECT PLANNING
36
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O 8024596/15VP/2019-11-15 | SICK
Subject to change without notice