EasyManua.ls Logo

SICK nanoScan3 I/O

SICK nanoScan3 I/O
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.2.3 Connecting cable with flying leads, 17-wire
Voltage supply and local inputs and outputs
F
lying leads
17-wire
Table 7: Pin assignment of the connecting cable with flying leads, 17-wire
Wire color Designation Function
Brown 24 V DC Supply voltage (+24 V DC)
Blue 0 V DC Supply voltage (0 V DC)
White OSSD 1.A OSSD pair 1, OSSD A
Green OSSD 1.B OSSD pair 1, OSSD B
Pink Uni-I/O 1 Universal I/O 1, configurable:
S
tatic control input B1
Universal input: sleep mode, restarting the device
Universal output: contamination, fault, reset required
(OSSD pair 1), monitoring result
Yellow Uni-I/O 2 Universal I/O 2, configurable:
OSSD pair 2, OSSD A (OSSD 2.A)
Static control input A1
Universal input: sleep mode, restarting the device
Universal output: contamination, error, monitoring
result
Black Uni-I/O 3 Universal I/O 3, configurable:
O
SSD pair 2, OSSD B (OSSD 2.B)
Static control input A2
Universal input: sleep mode, restarting the device
Universal output: contamination, error, monitoring
result
Gray Uni-I/O 4 Universal I/O 4, configurable:
Static control input B2
Universal input: sleep mode, restarting the device
Universal output: contamination, fault, reset required
(OSSD pair 2), monitoring result
Red Uni-in 1 Universal input 1, configurable:
Static control input C1
Dynamic control input 1a (0°)
Universal input: sleep mode, restarting the device
Violet Uni-in 2 Universal input 2, configurable:
S
tatic control input C2
Dynamic control input 1b (90°)
Universal input: sleep mode, restarting the device
Grey/Pink Uni-in 3 Universal input 3, configurable:
Static control input D1
Dynamic control input 2a (0°)
Universal input: sleep mode, restarting the device
Red/Blue Uni-in 4 Universal input 4, configurable:
Static control input D2
Dynamic control input 2b (90°)
Universal input: sleep mode, restarting the device
ELECTRICAL INSTALLATION 6
8024596/15VP/2019-11-15 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O
53
Subject to change without notice

Table of Contents