Tolerance band
A cont
our has a positive and a negative tolerance band. The cut-off path goes to the
OFF state if the safety laser scanner does not detect the contour inside the tolerance
band.
Positive tolerance (remote): the tolerance away from the safety laser scanner
Negative tolerance (near): the tolerance towards the safety laser scanner
7.10.1 Creating field set templates
Overview
If y
ou require the same combination of fields a number of times, you can create a field
set template.
Table 15: Manage field set templates
Manage field set templates
Approach
1.
Click on Add field set template.
2. Enter the name for the template.
3. Define the number of fields.
A selection field is shown for each field.
4. Select the Field types for the fields.
5. Enter the Field names.
6. Click on Apply.
The field set template is saved.
7.10.2 Importing and exporting field sets and fields
Overview
If y
ou need identical field sets or fields across different projects, you can export entire
field sets or individual fields out of one project and import them into another project.
Importing field sets and fields
1. Click on Import fields.
2. Select exported file with field set information.
A preview of the field sets and fields saved in the file will be shown.
3. Select the required field sets and fields.
4. Start the import.
The field sets and fields will be imported.
Exporting field sets and fields
1. Click on Export fields.
2. Select the relevant folder and enter a file name for storing the field set informa‐
tion.
3. Select the required field sets and fields.
4. Start the export.
The field sets and fields will be exported.
7.10.3 Background image
Overview
Y
ou can select a background image for the field editor. For example, the plan view of
the machine to be protected can be used as a sample.
CONFIGURATION 7