Table 9: User groups
User group Password Authorization
Machine operator No password required. Anyone can
lo
g on as a machine operator.
Ma
y read configuration from the
device.
Maintenance Deactivated ex-works, i.e. it is not ini‐
t
ially possible to log on as a mainte‐
nance technician. The user group
can be activated by the admin and
provided with a password.
Ma
y read configuration from the
device.
May transmit verified configura‐
tion to the device.
Change own password allowed.
Authorized client Deactivated ex-works, i.e. it is not ini‐
t
ially possible to log on as an autho‐
rized customer. The user group can
be activated by the admin and pro‐
vided with a password.
Ma
y read configuration from the
device.
May transmit verified and unveri‐
fied configuration to the device.
May verify configuration.
Resetting the safety function and
communication settings to factory
defaults is allowed.
Change own password allowed.
Changing the password of the
Maintenance user group is allowed.
Admin The password SICKSAFE is created at
t
he factory.
b
Change this password to protect
the device against unauthorized
access.
Ma
y read configuration from the
device.
May transmit verified and unveri‐
fied configuration to the device.
May verify configuration.
Resetting whole device to factory
settings allowed.
Activating and deactivating Main‐
tenance and Authorized customer
user groups is allowed.
Change own password allowed.
Changing the passwords of the
Maintenance and Authorized cus‐
tomer user groups is allowed.
The configuration of the device is saved in the system plug. Therefore, the passwords
ar
e retained when the device is replaced if the system plug is still used.
NOTICE
If you leave a computer that is connected to devices unattended, you must log out and
switch to the machine operator user group, so that unauthorized persons cannot transfer
configurations to the devices.
7.2.5 Settings
Information on the functionality and basic operation of the software and on the settings
in the main window can be found in the operating instructions of the Safety Designer
(part number 8018178).
7.2.6 Configuration
In the C
onfiguration, area you can compile the devices for a project. The available
devices can be found in the Device Catalog. The devices are displayed as Device tiles in
the working area.
CONFIGURATION 7
8024596/15VP/2019-11-15 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O
57
Subject to change without notice

Table of Contents

Related product manuals