OSSD 1.A
V
t
OSSD 1.B
V
t
t
S
t
S
t
S
t
S
t
S
t
S
t
S
t
S
t
S
OSSD 2.A
V
t
OSSD 2.B
V
t
Figure 54: Switch-off tests
t
S
Scan cycle time t
S
= 30 ms
OSSD 1.A
V
t
OSSD 1.B
V
t
≤ 300
µs
≤ 300
µs
S
4 × t
Figure 55: Duration and time offset for the switch-off tests in an OSSD pair
t
S
Scan cycle time t
S
= 30 ms
13.5 Sensing range
Protective field range
T
he effective protective field range depends on the object resolution that has been set.
Table 36: Protective field range
Resolution Protective field range
≥ 70 mm 3.00 m
60 mm 2.60 m
50 mm 2.15 m
40 mm 1.60 m
30 mm 1.25 m
20 mm 1.25 m
TECHNICAL DATA 13
8024596/15VP/2019-11-15 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O
117