EasyManua.ls Logo

SICK nanoScan3 I/O

SICK nanoScan3 I/O
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pin Designation Function
6 Uni-I/O 2 Universal I/O 2, configurable:
O
SSD pair 2, OSSD A (OSSD 2.A)
Static control input A1
Universal input: sleep mode, restarting the device
Universal output: contamination, error, monitoring
result
7 Uni-I/O 3 Universal I/O 3, configurable:
OSSD pair 2, OSSD B (OSSD 2.B)
Static control input A2
Universal input: sleep mode, restarting the device
Universal output: contamination, error, monitoring
result
8 Uni-I/O 4 Universal I/O 4, configurable:
Static control input B2
Universal input: sleep mode, restarting the device
Universal output: contamination, fault, reset required
(OSSD pair 2), monitoring result
9 Uni-in 1 Universal input 1, configurable:
Static control input C1
Dynamic control input 1a (0°)
Universal input: sleep mode, restarting the device
10 Uni-in 2 Universal input 2, configurable:
S
tatic control input C2
Dynamic control input 1b (90°)
Universal input: sleep mode, restarting the device
11 Uni-in 3 Universal input 3, configurable:
Static control input D1
Dynamic control input 2a (0°)
Universal input: sleep mode, restarting the device
12 Uni-in 4 Universal input 4, configurable:
Static control input D2
Dynamic control input 2b (90°)
Universal input: sleep mode, restarting the device
13 Uni-in 5 Universal input 5, configurable:
S
tatic control input E1
Universal input: resetting, (OSSD pair 1), sleep mode,
restarting the device
14 Uni-in 6 Universal input 6, configurable:
Static control input E2
Universal input: EDM (external device monitoring,
OSSD pair 1), sleep mode, restarting the device
15 Uni-in 7 Universal input 7, configurable:
Static control input F1
Universal input: resetting, (OSSD pair 2), sleep mode,
restarting the device
16 Uni-in 8 Universal input 8, configurable:
Static control input F2
Universal input: EDM (external device monitoring,
OSSD pair 2), sleep mode, restarting the device
17 nc Not connected
Thread FE Functional earth/shield
6 ELECTRICAL INSTALLATION
52
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 I/O 8024596/15VP/2019-11-15 | SICK
Subject to change without notice

Table of Contents