60
8014084/ZWT7/V3-1/2020-06 | SICKOPERATING INSTRUCTIONS | TRANSIC111LP
Subject to change without notice
4 OPERATION
4.18.3 Display errors detected (command ERRS)
Displays all errors active in the device.
Syntax: ERRS<cr>
Example:
4.18.4 Display Error Table (command ERRT)
Displays the Error Table.
Syntax: ERRT<cr>
Example:
>errs
ERROR: LOW SIGNAL
ERROR: FP SLOPE FAILURE
>
>errt
# :St :Cnt :CategoryError text
1:OFF: 0:FATALEEPROM BASIC PARAMS NOT AVAILABLE
2:OFF: 0:FATALEEPROM OPERATION PARAMS NOT AVAILABLE
...
31:OFF: 0:NON FATALSIGNAL LEVEL LOW
32:OFF: 0:NON FATALSIGNAL CUT
...
52:OFF: 0:WARNINGEEPROM LOG&STATS CORRUPTED
53:OFF: 0:WARNINGWATCHDOG RESET OCCURRED