5.9 Example 7: Password input mode (asterisk)
Example 7
To implement a field with hidden input, e.g. to enter a password, then display mode DT must
be set to 5. Asterisks are then displayed instead of the entered characters.
Figure 5-3 Password input mode (asterisk)
DEF VAR_SET_PWD=(S//""//DT5)
Variable type: STRING
Default setting: Empty string
Attributes:
Display mode DT: 5 (password input mode)
Variables
5.9 Example 7: Password input mode (asterisk)
SINUMERIK Integrate Run MyScreens (BE2)
Programming Manual, 12/2017, 6FC5397-1DP40-6BA1 91