EasyManuals Logo

Siemens MCP 398C Commissioning Manual

Siemens MCP 398C
1734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1545 background imageLoading...
Page #1545 background image
Service and diagnostics
5.3 Setting of the service switch (PCU 50.5 only)
PCU-Basesoftware (IM8)
Commissioning Manual, 02/2014, 6FC5397-1DP40-4BA0
125
5.3
Setting of the service switch (PCU 50.5 only)
Intended use
The "PCU Hardware Service" component as part of the PCU Base software provides a
function to read-out the switch positions.
Figure 5-2 Rotary coding switch (hexadecimal)
Meaning of switch positions
Only the settings of the service switch that are relevant for the commissioning engineer are
listed:
Switch setting
Mode of operation
Function
0
---
Normal operation (default setting)
6
Users
Reserved for additional software
9
Service
Headless operation without OP/TP
A
Service
Firmware recovery
C
Service
Checking
D
Service
Diagnostics
E
Service
Booting from the emergency boot system