6.2.13 RESOLUTION
Description
The RESOLUTION method is run through when the current resolution has changed for an
opened screen, i.e. typically at a TCU switchover.
Programming
Syntax: RESOLUTION
<instructions>
END_RESOLUTION
Description: Resolution
Parameters: - None -
See also
Variables S_RESX and S_RESY (Page 120)
6.2.14 RESUME
Description
The RESUME method is called when the screen was interrupted, e.g. for an area change, and
is now shown again. The value changes are processed again, if required, the timers started
and the RESUME block executed.
Programming
Syntax: RESUME
<instruction>
END_RESUME
Description: Screen active again
Parameters: - None -