All entries are in the section [ACCESSMASKS] and have the following form:
[ACCESSMASKS]
\wks.dir\*.wpd\*.mpf = 7777
\mpf.dir\*.mpf = 6577
\cus.dir\*.spf = 6577
See also
Definition of access levels (Page 37)
3.11.4 Access rights for files
Changing access rights
Access rights for execution, writing, listing and reading are displayed in the "Properties"
window.
Execute: is used for the selection for execution.
Write: controls the changing and deletion of a file or a directory.
For NC files, you have the option to set the access rights from keyswitch 0 to the current access
level, to be set separately for each file.
If an access level is higher than the current access level, it cannot be changed.
For external files (e.g. on a local drive), the access rights are displayed to you only if settings
have been executed for these files by the machine manufacturer. They cannot be changed via
the "Properties" window.
Note
Settings for the access rights to directories and files
Via the configuration file and MD51050, access rights of the directories and file types of the
NC memory and user memory (local drive) can be changed and pre-assigned.
Configuration file slfsfileattributes.ini
The access rights defined in the configuration file slfsfileattributes.ini and in MD51050 become
valid in the NC when creating new files and can then be changed individually in the Program
Manager with the "Properties" function. The access rights are an individual attribute of each
file in the NC.
The access rights defined in the configuration file slfsfileattributes.ini and MD51050 become
valid for external data on the CompactFlash Card of the NCU, or on the hard disk of the PCU/
PC immediately for all the specified directories and file types, and cannot be changed through
operation. The access rights can only be set globally for external data.
General settings
3.11 Access levels
SINUMERIK Operate (IM9)
42 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals