Page #1125 background imageLoading...
Page #1125 background image
Note
If errors occur when reading and writing drive parameters, the screen property ERR is set
appropriately.
Programming
Syntax: RDOP
("Identifier of the drive object", "Parameter number")
Description: Reading a drive parameter (Drive Object Parameter)
Parameter: Identifier of the drive object The identifier of the drive object
can be found in the "DO name"
column in "Drive system diag‐
nostics" in the diagnostics oper‐
ating area ( > ETC > HSK 8: drive
system) (see diagram below).
Parameter number
Figure 6-1 Identifier of the drive object
Syntax: MRDOP
("Identifier of the drive object", "Parameter number1"*"Pa‐
rameter number"[*…], Register index)
Description: Multi-read of drive parameters.
The MRDOP command transfers several drive parameters or drive
objects in a single register access. This access method is signifi‐
cantly faster than reading via individual access attempts.
Programming commands
6.3 Functions
SINUMERIK Integrate Run MyScreens (BE2)
Programming Manual, 12/2017, 6FC5397-1DP40-6BA1 139

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals