; usage as automation net (TCU boot support etc.) is possible
; by setting NetworkModel to "automation". (NCU only, Service
; and PCU20A variants!)
;NetworkModel=automation
; DisableSubsystems can be used to skip certain CFSes (= subsystems)
; a list of multiple names (separated by spaces) is possible
; a simple name means all CFSes with this name, an absolute path
; (e.g.,/siemens/sinumerik/nck) exactly this one CFS with
; the special value "ALL", all subsystems can be disabled
;DisableSubsystems=nck
; Directory for OEM netboot files (served by tftp to diskless clients)
NetbootDirectory=/oem/common/netboot
; Default security type for all CIFS mounts, if not given explicitly
; by sc connect -sec=TYPE. If not defined, NTLMv1 is used or NTLMv2
; if the server allows.
;DefaultCIFSSecurity=ntlmssp
; Properties of local time zone: names, offset, start and end day
; Some examples:
; Europe: WET0WEST,M3.5.0,M10.5.0
; CET-1CEST,M3.5.0,M10.5.0
; EET-2EEST,M3.5.0,M10.5.0
; USA: EST5EDT,M4.1.0,M10.5.0
; CST6CDT,M4.1.0,M10.5.0
; MST7MDT,M4.1.0,M10.5.0
; PST8PDT,M4.1.0,M10.5.0
; China: CST-8
; Japan: JST-9
Timezone=UTC
; TimezoneName(for-into-only-do-not-change)=Etc/Universal
; If DisablePLCTimeSync is set, no time synchronization with
Configuring the system
2.3 Configuration file "basesys.ini"
NCU operating system
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 35

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals