Basic procedure
On the PG/PC with Windows 7:
Connecting a PG/PC to a Siemens PC system according to one of the configurations shown
above.
The network protocol used is: TCP/IP.
TCP/IP is already pre-configured on the Siemens PC system.
Setting up IP addresses on the same subnetwork.
Releasing a directory on the PG/PC for network access.
On the Siemens PC system in the Service Center (WinPE):
On the PCU start the Service Center (WinPE).
Establish a network connection to the shared directory of the PG/PC.
See: Functions of the Service Center (Page 123)
Further information
Further information on the permissible network structures and network configurations can
be found in the SINUMERIK 840D sl Operator Components and Networking Manual.
Backing up and restoring data
6.12 Operating a service PC/PC in the network
PCU Base Software (IM10)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 143