1. CopyFileFromServer:
Allows copying file from SINUMERIK OPC UA server to client location.
The user shall provide the name of the file with full path to be copied.
On completion of the file transfer, an appropriate message will be displayed.
Type Data type Argument Description
in string SourceFile Name of the file need
to be copied with abso‐
lute path.
out ByteString Data Raw file data
2. CopyFileToServer:
Allows copying a client file to a specified SINUMERIK NC memory location.
The user shall select the file to be transferred and specify the location on server.
Type Data type Argument Description
in string TargetFilename Target file name with
absolute path
in ByteString Data Raw file Data
in Boolean Overwrite Overwrite True: Overwrite the file
if already exists. False:
File will not be overwrit‐
ten.
Out of security reasons only the following folders are accessible:
Part Programs
Sub_Programs
Workpieces.
Therefore only the following main paths will be accepted by the above mentioned methods:
Sinumerik/FileSystem/Part Program/
Sinumerik/FileSystem/Sub Program/
Sinumerik/FileSystem/Work Pieces/
Functionality
5.5 File transfer
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
Configuration Manual, 12/2017, 6FC5397-1DP40-6BA1 55

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals