Operating the device
5.2 Multi-monitoring
SIMATIC IPC PX-39A PRO
Operating Instructions, 11/2022, A5E51699950-AA
63
5.2 Multi-monitoring
You can operate several monitors on one device at the same time. You have the following
option for multi-monitoring:
Direct connection of the monitors to the two DisplayPort ports on the front of the device,
see "Connecting I/O devices (Page 56)"
See also
Important instructions and manuals for operating the device (Page 10)
Service and support (Page 122)
5.3 Monitoring of the device
5.3.1 Monitoring functions
You can monitor the following device functions with the SIMATIC IPC DiagBase or SIMATIC IPC
DiagMonitor software:
Monitoring
Description
Status displays and actions
Temperature monitor-
ing
Monitoring for temperature high and low limits as
well as cable breaks of the temperature sensors
Temperature sensors record the temperature at criti-
cal device points, e.g. at the processor.
The temperature thresholds are defined for the indi-
vidual temperature sensors.
With SIMATIC IPC DiagBase or SIMATIC IPC DiagMoni-
tor, actions are triggered when the temperature high
or low thresholds are exceeded.
Temperature alarm is generated.
Watchdog
Monitoring of the system status and message to de-
termine if a station is still operational
If the watchdog is not addressed within a configured
monitoring time, a watchdog alarm is output.
A change to the monitoring time is effective immedi-
ately.
Depending on the setting, the following
actions are triggered:
Reset on: Hardware reset is per-
formed
Reset off: No action is performed
The device is restarted
The device is shut down