Problem
Cause
Remedy
USB device not responding
USB ports are deactivated in the
firmware (BIOS)
Use a different USB port or activate the port.
Operating system does not support
XHCI
Activate the firmware setting "PS/2 Emulation" in the
firmware (BIOS) under "Advanced > USB Configura-
tion".
USB-2.0/3.0 device connected
although USB-2.0/3.0 is deactivated
Activate the USB.
Operating system does not support
the USB interfaces
Activate the firmware setting "Legacy USB Sup-
port" in the firmware (BIOS) under "Advanced >
USB Configuration".
For other devices, you need the USB device driv-
ers for the required operating system.
"chkdsk" is not functioning
EWF (Enhanced Write Filter) has
been activated. The "chkdsk" com-
mand is not supported if the EWF
has been activated.
Deactivate the EWF or use an alternative method to
"chkdsk".
B.2.2 Problems when booting the device
Problem
Cause
Remedy
After changing the hard disk,
"None" is indicated for the
relevant SATA port.
System is booted without function-
ing drive.
Reboot the system with a functioning hard disk.
Computer does not boot or
"Boot device not found" is
displayed.
The boot medium is not approved
Set the boot priority to "Enabled" in the firmware
(BIOS) under "Boot > Boot device".
The boot device is not in first place
of the boot priority in the BIOS
setup
Change the boot priority in the firmware (BIOS) un-
der "Boot > Boot device".
The boot data storage medium is
set up with GPT, and UEFI boot is
deactivated in the firmware (BIOS)
Activate UEFI mode in the firmware (BIOS).
The startup of a Windows
operating system located on a
GPT data storage medium is
aborted with the following
error message:
"Status: 0xc0000225 Info: The
boot selection failed because a
required device is inaccessible"
The settings in the boot loader file
"BCD" are incorrect or damaged.
Restore the Windows® operating system.
You can find the files and descriptions needed for
this on the supplied data storage medium.

Table of Contents

Other manuals for Siemens SIMATIC IPC347G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC347G and is the answer not in the manual?

Siemens SIMATIC IPC347G Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC347G
CategoryIndustrial PC
LanguageEnglish

Related product manuals