Technical specifications
8.5 Ambient conditions
SIMATIC IPC347G
72 Operating Instructions, 10/2020, A5E50059993-AA
Immunity to RF interference
Radiation Immunity (according to IEC 61000-4-3)
10 V/m; 80 up to 1000 MHz
80% AM (1 kHz)
3 V/m; 1.4 to 2 GHz
80% AM (1 kHz)
3 V/m; 2 to 6 GHz
80% AM (1 kHz)
Conducted Immunity (according to IEC 61000-4-6)
150 kHz to 80 MHz: 10 V, 80% AM (1 kHz)
Magnetic field
30 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8)
8.5 Ambient conditions
See the note in "Applicability of technical specifications (Page 69)".
Climatic ambient conditions
Temperature
Tested according to IEC 60068-2-2; IEC 60068-2-1; IEC 60068-2-14
Operation
+5 °C up to +40 °C
Gradient: 10 K/h; no condensation
Storage/transport
20 °C up to +60 °C
Gradient: 20 K/h; no condensation
Relative humidity
Tested according to IEC 60068-2-78; IEC 60068-2-30
Operation
5% up to 80% at 25 °C; no condensation
Gradient: 10 K/h; no condensation
Storage/transport
5% up to 95% at 25 °C; no condensation
Gradient: 20 K/h; no condensation
Atmospheric pressure
Operation
1013 up to 795 hPa,
corresponds to an altitude of 0 m to 2000 m
Storage/transport
1013 up to 660 hPa,
Corresponds to an altitude of 0 m to 3500 m
Mechanical ambient conditions
Vibration
Tested according to IEC 60068-2-6;
Operation
With HDD: 10-58 Hz: 0.015mm; 58-200 Hz:1.96 m/s2; 10 cycles
With SSD: 10-58 Hz: 0.0375mm; 58-200 Hz:4.9 m/s2; 10 cycles
Storage/transport
5 to 8.4 Hz, amplitude 3.5 mm; 8.4 to 500 Hz: 9.8 m/s2
Resistance to shock
Tested in accordance with IEC 60068-2-27
Operation
With HDD: Half-sine: 9.81 m/s2, 20 ms, 3 shocks per axis
With SSD: Half-sine: 150 m/s2, 11 ms, 3 shocks per axis
Storage/transport
Half-sine; 250 m/s
2
; 6 ms; 1000 shocks per axis
Special features
Quality assurance
In accordance with ISO 9001
Altitude of operation (m)
Up to 2000 m

Table of Contents

Other manuals for Siemens SIMATIC IPC347G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC347G and is the answer not in the manual?

Siemens SIMATIC IPC347G Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC347G
CategoryIndustrial PC
LanguageEnglish

Related product manuals