R 02/92
Matching Module 2 for Absolute Encoders
5.3.5 Layout
20
17
15
R106
D
R103
rl
R104
II
R105
II
R107
rl
:21
❑
(!
T
R5
R4
r4
.1 .2
0
R20
R13
1!
*
Corresponds to the
capacitors Cl to C20
The layout shows the configurable elements, jumpers, and switches.
5.3.6 Switch Diagram of the Input Amplifiers
100 %“ PIN13
‘----7=G----------
r%
I
H-i
--------*--------,
-------
--
The voltage at the respective Schmitt Trigger (i.e., via
R106
or R107) must be
<0.8
V for low level and a minimum of 3 V or a maximum of 5 V for high level!
1P
241 Equipment Manual
@
Siemens AG 1989, Order No.: 6ES5
998-0KD21
5–7
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com