4
01.99
4.10 Linear motors (1FN1, 1FN3 motors)
4-170
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
2. Mechanical system
Is the axis easy to move over the complete traversing range?
Does the air gap between the primary and secondary section
and the mounting dimensions correspond to the motor manufac-
turer’s data (refer to Chapter 4.10.4)?
Suspended/hanging axis:
If weight equalization is being used for the axis, is this func-
tional?
Brake:
If a brake is being used, is it correctly controlled?
Traversing range limiting:
Are the mechanical end stops available and tightly bolted to both
ends of the traversing path?
Are the moving feeder cables correctly routed in a cable drag
assembly?
3. Measuring system (refer to Chapter 4.10.6)
Which measuring system is being used? _ _ _ _ _ _ _ _ _ _ _ _
Absolute or incremental abs incr
Grid spacing _ _ _ _ _ _ _ _ _ _ µm
Zero marks (number and position) _ _ _ _ _ _ _ _ _ _ _ _
Which is the positive drive direction? (refer to Chapter 4.10.6)
Which is the positive counting direction of the measuring
system?
Invert (P1011.0)? yes no
4. Connecting–up
Power module (connect UVW, phase sequence, clockwise rotat-
ing field)
Protective conductor connected?
Screen connected?
Temperature monitoring circuits:
Are the cables connected to the terminal block of the screen con-
necting plate?
––> Temperature sensor (Temp–F):
The average absolute winding temperature can be
measured using the temperature sensor (Temp–F).
––> Overtemperature switch (Temp–S)
The individual motor phase windings can be digitally monitored
for overtemperature using the overtemperature trip
circuit (Temp–S).