4
01.99
4.10 Linear motors (1FN1, 1FN3 motors)
4-171
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
!
Danger
The circuits of Temp–F and Temp–S neither have ”protective
separation” between each other nor to the power circuits in
accordance with VDE 0160/EN 50178.
This is the reason that they may not be considered as SELV/PELV
circuit nor may they be connected with such circuits. Also refer to
Reference: /PJLM/ Configuration Manual
1FN1, 1FN3 Linear Motors
Section ”General information on the connection
system (CON)”
Temperature sensor evaluation (refer to Chapter 4.10.5)
Readers note
Section ”General information on the connection system (CON)” in:
Reference: /PJLM/ Configuration Manual,
1FN1, 1FN3 Linear Motors
5. Measuring system cable
Is the measuring system cable inserted at X411/X412 or at the
adapter connector of the temperature sensor coupling cable?
!
Danger
Presently, the connection does not correspond to ”protective
separation” according to VDE 0160/EN 50178.
This is the reason that they may not be considered as SELV/PELV
circuit nor may they be connected with such circuits. Also refer to
Reference: /PJLM/ Configuration Manual
1FN1, 1FN3 Linear Motors
Section ”General information on the connection
system (CON)”