5
5.6 Net data (PKW and PZD area)
5-268
 Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 5-25 Parameters for configuring the process data, continued
No. EffectiveUnitsMax.StandardMin.Name
P0922 = 107 Standard telegram 107, n
set
interface with KPC (DSC) and encoder 1 and
encoder 3
from
SW 4.1
This process data is associated with the encoder interface (refer to Chapter 5.6.4)
PZD1
STW1
ZSW2
PZD1
ZSW1
PZD 4
Setpoint
Actual point
PZD 4
STW2
PZD 5
MomRed
PZD 6
G1_ZSW
PZD 7 PZD 8
G1_XIST1
PZD 9 PZD 10
G1_XIST2
PZD 6
G1_STW
MeldW
PZD 5
P0915
:1
50001
P0915
:4
50003
P0916
:1
50002
P0916
:4
50004
P0916
:5
50102
P0915
:5
50101
P0915
:6
50009
P0916
:6
50010
P0916
:7
50011
P0916
:8
50011
P0916
:9
50012
P0916
:10
50012
PZD 7
G3_STW
P0915
:7
50017
PZD 11
G3_ZSW
PZD 12 PZD 13
G3_XIST1
PZD 14 PZD 15
G3_XIST2
P0916
:11
50018
P0916
:12
50015
P0916
:13
50015
P0916
:14
50016
P0916
:15
50016
Actual
point
PZD2 PZD 3
NSOLL_B
P0915
:2
50007
P0915
:3
50007
PZD2 PZD 3
NIST_B
P0916
:2
50008
P0916
:3
50008
PZD 8 PZD 9
XERR
P0915
:8
50025
P0915
:9
50025
PZD 10 PZD 11
KPC
P0915
:10
50026
P0915
:11
50026
P0922 = 108 Standard telegram 108, positioning, master drive for the position reference
value coupling (publisher)
from
SW 4.1
PZD1
STW1
ZSW2
PZD1
ZSW1
PZD 4
Actual point
PZD 4
STW2
PZD 5
Over
PZD 6 PZD 7
XsollP
PZD 9 PZD 10
XcorMeldW
PZD 5
P0915
:1
50001
P0915
:4
50003
P0916
:1
50002
P0916
:4
50004
P0916
:5
50102
P0915
:5
50205
P0916
:6
50208
P0916
:7
50208
P0916
:9
50210
P0916
:10
50210
PZD2 PZD 3
SatzAnw
P0915
:2
50201
P0915
:3
50203
PZD2 PZD 3
AktSatz
P0916
:2
50202
P0916
:3
50204
Setpoint
PosStw
PosZsw QZsw
PZD 8
P0916
:8
50118