5.6 Net data (PKW and PZD area)
5-269
 Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 5-25 Parameters for configuring the process data, continued
No. EffectiveUnitsMax.StandardMin.Name
P0922 = 109 Standard telegram 109, positioning, slave drive for the position reference
value coupling (subscriber)
from
SW 4.1
PZD1
STW1
PZD 4
STW2
PZD 5
Over
P0915
:1
50001
P0915
:4
50003
P0915
:5
50205
PZD2 PZD 3
SatzAnw
P0915
:2
50201
P0915
:3
50203
PosStw
Setpoint
PZD 6 PZD 7
Xext
PZD 9 PZD 10
XcorExt
P0915
:6
50207
P0915
:7
50207
P0915
:9
50209
P0915
:10
50209
QStw
PZD 8
P0915
:8
50117
ZSW2
PZD1
ZSW1
PZD 4
Actual
point
PZD 6 PZD 7
XistPMeldW
PZD 5
P0916
:1
50002
P0916
:4
50004
P0916
:5
50102
P0916
:6
50206
P0916
:7
50206
PZD2 PZD 3
AktSatz
P0916
:2
50202
P0916
:3
50204
PosZsw
P0922 = 110 Standard telegram 110, positioning with MDI
(from
SW 7.1)
PZD1
STW1
PZD 4
STW2
PZD 5
Over
P0915
:1
50001
P0915
:4
50003
P0915
:5
50205
PZD2 PZD 3
SatzAnw
P0915
:2
50201
P0915
:3
50203
PosStw
Setpoint
PZD 6 PZD 7
MDIPos
PZD 8 PZD 9
MDIVel
P0915
:6
50221
P0915
:7
50221
P0915
:8
50223
P0915
:9
50223
ZSW2
PZD1
ZSW1
PZD 4
Actual
point
PZD 6 PZD 7
XistPMeldW
PZD 5
P0916
:1
50002
P0916
:4
50004
P0916
:5
50102
P0916
:6
50206
P0916
:7
50206
PZD2 PZD 3
AktSatz
P0916
:2
50202
P0916
:3
50204
PosZsw
PZD 10
MDIAcc
P0915
:10
50225
PZD 11 PZD 12
MDIDec
P0915
:11
50227
P0915
:12
50229
MDIMode
5 Communications via PROFIBUS DP
08.99
02.03

Table of Contents