6
6.4 Input/output terminals of the control board
6-476
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-44 Overview of the input signals
Operating
mode
Signal name, description Fct. No. n–set pos PROFIBUS bit
Inactive 0 x x –
Reset the fault memory 3 x x STW1.7
Open–loop torque controlled mode 4 x – STW1.14
Motor data set changeover (from SW 2.4)
1st input/2
0
2nd input/2
1
5
6
x
x
–
–
STW2.9
STW2.10
Ramp–up time zero 7 x x STW2.4
Integrator inhibit, speed controller 8 x x STW2.6
Parameter set changeover
1st input/2
0
2nd input/2
1
3rd input/2
2
9
10
11
x
x
x
x
x
x
STW2.0
STW2.1
STW2.2
Fixed speed setpoint (from SW 3.1)
1st input/2
0
2nd input/2
1
3rd input/2
2
4th input/2
3
15
16
17
18
x
x
x
x
–
–
–
–
–
–
–
–
First speed setpoint filter off 25 x x STW2.3
Suppress fault 608 (from SW 3.1) 26 x x STW2.8
Spindle positioning on (from SW 5.1) 28 x – STW1.15
ON/OFF 1 (from SW 8.3) 31 (from
SW 8.3)
x x STW1.0
Operating condition/OFF 2 32 (from
SW 4.1)
x x STW1.1
Operating condition/OFF 3 33 (from
SW 5.1)
x x STW1.2
Enable inverter/pulse inhibit 34 (from
SW 4.1)
x x STW1.3
Ramp–function generator enabled 35 x – STW1.4
Selection, parking axis 40 x x STW2.7
Opening the holding brake for test purposes (from
SW 4.1)
42 x x STW1.12
Block selection 1st input/2
0
2nd input/2
1
3rd input/2
2
4th input/2
3
5th input/2
4
6th input/2
5
50
51
52
53
54
55
x
x
x
x
x
x
x
x
x
x
x
x
SatzAnw.0
SatzAnw.1
SatzAnw.2
SatzAnw.3
SatzAnw.4
SatzAnw.5
Operating condition/reject traversing task 58 – x STW1.4
Operating condition/intermediate stop 59 – x STW1.5
Activate traversing task (edge) 60 – x STW1.6
Incremental jogging (from SW 4.1) 61 – x PosStw.5
6 Description of the Functions
08.0104.05