6
6.4 Input/output terminals of the control board
6-510
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-49 List of output signals, continued
Operating
mode
Signal name, description PROFIBUS bitposn–setFct. No.
Spindle positioning on (from SW 5.1) 28 x ZSW1.15
This signal displays as to whether the ”spindle positioning” function has been activated.
1 signal ”Spindle positioning” function is active
0 signal Function is not active
Note:
Refer under the index entry ”Input signal – spindle positioning on”
The ”spindle positioning” function is described in Chapter 6.15 (from SW 5.1)
Warning present/no warning present 29 (from
SW 3.3)
x x ZSW1.7
The output signal indicates whether the drive is signaling at least one warning.
1 signal Warning present
Which warning(s) is(are) present?
This can be identified by evaluating P0953 to P0960 (Warnings 800 to 927) (refer to
Chapter 5.9).
0 signal Warning not present
DC link monitoring V
DC
link
> V
x
30 x x MeldW.4
This output signal is used to display whether the DC link voltage (V
DC
link
) is less than or greater than the
selected DC link undervoltage warning threshold (V
x
, P1604).
V
x
t
1 signal
0 signal
V
DC
link DC link voltage
V
x
(P1604)
V
DC
link
> V
x
V
DC
link
< V
x
V
DC
link
> V
x
V
DC
link
> V
x
Fault present/no fault present 31 x x ZSW1.3
The output signal indicates whether the drive is signaling at least one fault.
1 signal Fault present
There is at least one fault present.
The cause of the fault or faults which is (are) present, must be removed and the fault then
acknowledged.
0 signal No fault present
Note:
Refer to Chapter 7 for information on the faults as well as their acknowledgment.
Status, controller enable 32 x x ZSW1.2
This output signal is used to display whether the speed controller is active and is ready to accept speed
setpoints.
1 signal The speed controller is active and setpoints can be accepted
0 signal The speed controller is not active