6.4 Input/output terminals of the control board
6-516
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-49 List of output signals, continued
Operating
mode
Signal name, description PROFIBUS bitposn–setFct. No.
Reference position reached/outside reference posi-
tion
60 x ZSW1.10
tion
x Meldw.14
This output signal is used to display, in the positioning mode (ZSW1.10), whether the axis has reached
the end of the traversing block (position reference value = target position) and the position actual value
lies within the positioning window (P0321).
In the n–set mode, MeldW.14 indicates that the reference position has been reached when positioning
the spindle
1 signal Reference position reached
The axis/spindle is at the end of a traversing task and the position monitoring time
(P0320) has expired within the positioning window (P0321).
0 signal Outside the reference position
The axis/spindle is outside the positioning window.
Note:
The signal is not set when the axis stops, if
the axis is in the closed–loop speed controlled jogging mode
an ongoing traversing block is interrupted or canceled using ”intermediate stop” or ”stop” which
means that the target position has not been reached
The signal remains set, until
a new traversing block is started
the axis is traversed in the jogging mode
a reference point approach is started
a fault (alarm) occurs (e.g. one of the monitoring windows P0318, P0321 or P0326) has been ex-
ceeded
The signal remains set if a traversing block is re–started and there is no difference between the target
position and the previous position.
Reference point set/no reference point set 61 x ZSW1.11
The output signal indicates whether an axis is referenced.
When referencing, the incremental measuring system of the axis is synchronized with the drive.
1 signal Reference point set
The axis has a valid reference point.
0 signal Reference point set
The axis does not have a valid reference point.
Note:
The following functions are not effective for an axis which is not referenced:
Software limit switch
Backlash compensation
Start the traversing blocks
6 Description of the Functions
01.99
! 611ue diff !
08.0107.03