6
6.7 Analog outputs
6-544
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-55 Parameter overview for the analog outputs, continued
Terminals Parameters
No. Ef-
fec-
tive
UnitsMax.Stan-
dard
Min.NameNo.Desig-
nation
0633 Signal number
analog output terminals 16.x/15
0 35 530 – Im-
medi-
ately
Note: refer to the description of P0626 for terminal 75.x/15
0634 Shift factor
analog output terminals 16.x/15
0 0 47 – Im-
medi-
ately
Note: refer to the description of P0627 for terminal 75.x/15
16.A
16.B
X441.2
X441.4
0635 Offset analog output terminal
16.x/15
–128 0 127 – Im-
medi-
ately
15
X441.5
Note: refer to the description of P0628 for terminal 75.x/15
0638 Overcontrol protection,
analog output terminal 16.x/15
0 1 1 – Im-
medi-
ately
Note: refer to the description of P0631 for terminal 75.x/15
0639 Smoothing time
analog output terminal 16.x/15
0.0 0.0 1 000.0 ms Im-
medi-
ately
Note: refer to the description of P0632 for terminal 75.x/15
– – 0623
Signal
No. 34
DAU normalization, speed actual
value (SRM, ARM)
DAU normalization, actual motor
velocity (SLM)
–200.0 100.0 200.0 %
Im-
medi-
ately
... defines, for the output of ”absolute motor speed, finely normalized” (Signal
No. 34), which voltage is output at the maximum speed n
max
.
The maximum speed n
max
is given by:
for SRM: minimum (1.2 x P1400, P1147)
for ARM/SLM: minimum (P1146, P1147)
10 V
5 V
0.5 n
max
200 %
100 %
50 %
Examples:
P0623 = 100 % –> +10 V n
max
P0623 = 50 % –> +5 V n
max
P0623 = 200% –> +10 V 0.5 n
max
P0623 = –50% –> –5V n
max
n
max
U [V]
| n
act
|
6 Description of the Functions
02.02