6.7 Analog outputs
6-545
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-55 Parameter overview for the analog outputs, continued
Terminals Parameters
No. Ef-
fec-
tive
UnitsMax.Stan-
dard
Min.NameNo.Desig-
nation
– – 0624
Signal
No. 35
DAU normalization, motor utiliza-
tion
–200.0 100.0 200.0 % Im-
medi-
ately
... defines, for the output of ”utilization (M
set
/M
set,
limit
, finely normalized” (Signal
No. 35) which voltage is obtained when
|maximum torque| (at n = 0 to n
rated
)
|power| (at n > n
rated
).
is reached.
Examples: P0624 = 100 % –> +10 V Max. torque or power
P0624 = 50 % –> +5 V Max. torque or power
– – 0625
Signal
No. 36
D/A normalization, torque setpoint
(SRM, ARM)
D/A normalization, force setpoint
(SLM)
–200.0 100.0 200.0 %
Im-
medi-
ately
... defines for the output of ”torque setpoint, finely normalized” (Signal No. 36),
which voltage is output when 200% rated torque is reached.
Examples: P0625 = 100 % –> +10 V twice the rated torque
P0625 = 50 % –> +5 V twice the rated torque