6
6.7 Analog outputs
6-546
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-56 Signal selection list for analog outputs
Signal Operating
mode
Displayed
in
Shif
t
fac
-
tor
Bit
width
Units Normaliza-
tion
(corre-
sponds
No. Designation n–set pos
tor
(corre-
sponds
to LSB)
0 No signal x x
1 Physical address x x 0 24
2 Current act. value, phase U x x 4 24 A
pk
P1710
3 Current actual value, phase V x x 4 24 A
pk
P1710
4 Field–generating current ac-
tual value I
d
x x 4 24 A
pk
P1710
5 Torque–generating current
actual value I
q
x x P1708 (%)
P1718 (A)
4 24 A
pk
P1710
6 Current setpoint I
q
(limited after the filter)
x x 4 24 A
pk
P1710
7 Current setpoint I
q
(in front of
the filter)
x x 4 24 A
pk
P1710
8 Speed actual value, motor
(SRM, ARM)
x
x
P0602
6
24
RPM
P1711
Velocity actual value, motor
(SLM)
x
x
P0602
6
24
m/min
P1711
9 Speed setpoint (SRM, ARM)
x
x
P0601
(only for
controller
6
24
RPM
P1711
Velocity setpoint (SLM)
x
x
(only for
controller
enable)
6
24
m/min
P1711
10 Speed setpoint, reference
model (SRM, ARM)
x
x
6
24
RPM
P1711
Velocity setpoint, reference
model (SLM)
x
x
6
24
m/min
P1711
11 Torque setpoint (speed con-
troller output) (SRM, ARM)
x
x
P1716
4
24
Nm
P1713
Force setpoint (speed con-
troller output) (SLM)
x
x
P1716
4
24
N
P1713
12 Torque setpoint limit (pos.)
(SRM, ARM)
x
x
4
24
Nm
P1713
Force setpoint limit (pos.)
(SLM)
x
x
4
24
N
P1713
13 Motor utilization
max (M
set
/M
max,
p
set
/p
max
)
x x P0604 8 16 % 8000H
100%
14 Active power x x 12 16 kW 0.01 kW
15 Rotor flux setpoint x x 1 24 Vs P1712
16 Rotor flux actual value x x 1 24 Vs P1712
Signal selection list
for analog output
6 Description of the Functions
01.99
04.99

Table of Contents