6
6.7 Analog outputs
6-547
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-56 Signal selection list for analog outputs, continued
Signal Normaliza-
tion
(corre-
sponds
to LSB)
UnitsBit
width
Shift
fac-
tor
Displayed
in
Operating
mode
No.
Normaliza-
tion
(corre-
sponds
to LSB)
UnitsBit
width
Shift
fac-
tor
Displayed
in
posn–setDesignation
17 Quadrature voltage V
q
x x – 11 24 V P1709 V
DC
link
/2
18 Direct–axis voltage V
d
x x – 11 24 V P1709 V
DC
link
/2
19 Current setpoint I
d
x x – 4 24 A
pk
P1710
20 Motor temperature x x P0603 13 24 °C 0.1 °C
21 DC link voltage at the NE
module
x x P1701 13 24 V 1 V
22 Zero mark signal, motor mea-
suring system
x x – 17 16 – –
23 Bero signal/equivalent zero
mark (bit 11, inverted)
x x – 12 16 – –
24 Absolute speed actual value
(SRM, ARM)
RPM
Absolute velocity actual value
(SLM)
m/min
25 Slip frequency setpoint x x – 8 24 1/s
2000 x 2
800000H x 1s
26 Zero mark signal, direct mea-
suring system
x x – 17 24 – –
27,
28
Reserved – – – – – – –
29 Actuator voltage, Q input x x – 11 24 V P1709 V
DC
link
/2
30 Actuator voltage, D input x x – 11 24 V P1709 V
DC
link
/2
31 Normalized, electrical rotor
position
(10 000 hex = 360°)
x x – 7 24 De-
grees
–
32 Absolute voltage setpoint x x P1705 11 24 V P1709
33 Absolute current actual value x x P1719 4 24 A
pk
P1710
34 Absolute speed actual value
(finely normalized) (SRM,
ARM)
RPM
Absolute velocity actual value
(finely normalized) (SLM)
Note: P0623 is the reference
m/min
35 Utilization (finely normalized)
Note: P0624 is the reference
x x – 0 24 % P1741
6 Description of the Functions
04.9908.01