6
6.7 Analog outputs
6-548
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-56 Signal selection list for analog outputs, continued
Signal Normaliza-
tion
(corre-
sponds
to LSB)
UnitsBit
width
Shift
fac-
tor
Displayed
in
Operating
mode
No.
Normaliza-
tion
(corre-
sponds
to LSB)
UnitsBit
width
Shift
fac-
tor
Displayed
in
posn–setDesignation
36 Torque setpoint (finely
normalized) (SRM, ARM)
Nm
Force setpoint (finely normal-
ized) (SLM)
Note: P0625 is the reference
x x – 0 24 N P1742
37 Speed setpoint at terminals
56.x/14.x, 24.x/20.x (SRM,
ARM)
RPM
Velocity setpoint at terminals
56.x/14.x, 24.x/20.x (SLM)
m/min
38 Signal DAU1 from
PROFIBUS–PPO
x x – 0 16 – –
39 Signal DAU2 from
PROFIBUS–PPO
x x – 0 16 – –
40 Speed setpoint from
PROFIBUS PPO (SRM,
ARM)
RPM
Velocity setpoint from
PROFIBUS PPO (SLM)
m/min
41 Rotor position, finely/coarsely
synchronized (from SW 5.1)
0: Still not synchronized
1: Coarsely synchronized
3: Coarsely and finely syn-
chronized
x x – 21 16 – –
42 Input terminals (refer to
P0678) (from SW 5.1)
x x – 7 16 – –
43 Torque setpoint limit (neg.)
(SRM, ARM)
Force setpoint limit (neg.)
(SLM) (from SW 7.1)
x x – 4 24 Nm
N
P1713
44 Speed correction value
(SRM, ARM)
Velocity correction value
(SLM) (from SW 7.1)
x x – 0 24 RPM
m/min
P1711
45
to
69
Reserved – – – – – – –
70 Position controller output
(SRM, ARM)
RPM
(SLM)
m/min
6 Description of the Functions
04.9902.03