EasyManua.ls Logo

Siemens SIMODRIVE 611 universal - Page 582

Siemens SIMODRIVE 611 universal
930 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
6.11 Motor changeover for induction motors (from SW 2.4)
6-582
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-61 Motor data set–dependent parameters, continued
Motor data set Meaning
1432
1127 2127 3127 4127 Voltage at f = 0, V/Hz operation
1129 2129 3129 4129 cos phi power factor
1130 2130 3130 4130 Rated motor power
1132 2132 3132 4132 Rated motor voltage
1134 2134 3134 4134 Rated motor frequency
1135 2135 3135 4135 Motor no–load voltage
1136 2136 3136 4136 Motor no–load current
1137 2137 3137 4137 Stator resistance, cold
1138 2138 3138 4138 Rotor resistance, cold
1139 2139 3139 4139 Stator leakage reactance
1140 2140 3140 4140 Rotor leakage reactance
1141 2141 3141 4141 Magnetizing reactance
1142 2142 3142 4142 Speed at the start of field weakening
1145 2145 3145 4145 Stall (standstill) torque reduction factor
1146 2146 3146 4146 Maximum motor speed
1147 2147 3147 4147 Speed limiting
1148
1)
2148
1)
3148
1)
4148
1)
Speed at the start of the stall power
1150 2150 3150 4150 P gain, flux controller
1151 2151 3151 4151 Integral action time, flux controller
1160 2160 3160 4160 Speed at the start of flux sensing
1180 2180 3180 4180 Lower current limit adaptation
1181 2181 3181 4181 Upper current limit adaptation
1182 2182 3182 4182 Factor, current controller adaptation
1230:8 2230:8 3230:8 4230:8 1st torque limit value
1233:8 2233:8 3233:8 4233:8 Regenerative limiting
1235:8 2235:8 3235:8 4235:8 1st power limit value
1238 2238 3238 4238 Current limit value
1240:8 2240:8 3240:8 4240:8 Offset, torque setpoint (speed controlled)
1241:8 2241:8 3241:8 4241:8 Normalization, torque setpoint
1242:8 2242:8 3242:8 4242:8 Offset, torque setpoint (torque controlled)
1243:8 2243:8 3243:8 4243:8 Normalization, torque/power reduction
1245 2245 3245 4245 Threshold for speed–dep. Msoll smoothing
1246 2246 3246 4246 Hysteresis for speed–dep. Msoll smoothing
1256:8 2256:8 3256:8 4256:8 Ramp–function generator, ramp–up time
1257:8 2257:8 3257:8 4257:8 Ramp–function generator, ramp–down time
6 Description of the Functions
01.99
04.99
! not 611ue !

Table of Contents