039 Error during power section identification. Supplemen-
tary info: \%X
Cause Supplementary information
0x100000:
More than 1 power section type was identified.
0x200000:
No power section type was identified, although it would have been pos-
sible.
0x30xxxx:
The identified power module differs from the entered PM (P1106). To
xxxx: the code of the identified PM is entered here.
0x400000:
Different power section codes (P1106) are entered for this 2-axis module.
Remedy – Execute RESET or POWER ON
– Check whether the control module is correctly inserted in the power
module
Acknowledgement POWER ON
Stop response STOP II (SRM, SLM) STOP I (ARM)
040 Expected option module is not available.
Cause The parameterization (P0875) expects an option module which is not
available on this control module.
Remedy Compare the type of the expected option module (P0875) with the type
of the inserted option module (P0872) and check/replace the inserted
option module or cancel the option module with P0875 = 0.
Acknowledgement POWER ON
Stop response STOP II (SRM, SLM) STOP I (ARM)