7
7.3 List of faults and warnings
7-677
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
703 Invalid current controller cycle
Cause An illegal value was entered in P1000.
Remedy Enter a valid value in P1000.
Permissible values for P1000 are:
2 (62.5 µs) for single-axis positioning or for speed setpoint input
4 (125 µs) in each operating mode
Acknowledgement POWER ON
Stop response STOP II (SRM, SLM) STOP I (ARM)
704 Invalid speed controller cycle
Cause An illegal value was entered in P1001.
Remedy Enter a valid value in P1001.
Permissible values for P1001 are 2 (62.5 us), 4 (125us), 8 (250us), 16
(500us).
Setting 2 (62.5us) is only permissible for single-axis operation.
Further, P1001 must be >= P1000.
Acknowledgement POWER ON
Stop response STOP II (SRM, SLM) STOP I (ARM)
705 Invalid position controller cycle
Cause The monitoring function identified a position controller cycle (P1009)
outside the permissible limits.
Remedy Enter a valid value in P1009.
Permissible values for P1009 lie between 32 (1 ms) and 128 (4ms).
Further, the position control cycle must be a integral multiple of the
speed control cycle.
Acknowledgement POWER ON
Stop response STOP II (SRM, SLM) STOP I (ARM)
706 Invalid interpolation cycle
Cause The monitoring has identified an interpolation cycle (P1010) outside the
permissible limits, or an illegal ratio between the interpolation cycle and
the position controller cycle (P1009).
Remedy Enter a valid value in P1010 or correct P1009.
Permissible values for P1010 lie between 128 (4ms) and 640 (20ms)
or, only for the 1-axis version, also 64 (2ms) if P1009 is also 64 (2ms).
Further, the interpolation cycle must be an integral multiple of the posi-
tion controller cycle.
Acknowledgement POWER ON
Stop response STOP II (SRM, SLM) STOP I (ARM)