7
7.4 Commissioning functions
7-725
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0 (LSB
23 (MSB)Bit 781516
with shift factor = 0
with shift factor = 1
with shift factor = 8
with shift factor = 16
MSB = Most Significant Bit
LSB = Least Significant Bit
Analog output value
Fig. 7-8 Shift factor for analog output of 24–bit signals
0 (LSB
47 (MSB)Bit 783940
with shift factor = 0
with shift factor = 1
with shift factor = 8
with shift factor = 40
Analog output value
MSB = Most Significant Bit
LSB = Least Significant Bit
Fig. 7-9 Shift factor for analog output of 48–bit signals
Shift factor = 0
Shift factor = 2
200000H
0 V
2.5 V
+ 5 V
Output
voltage [V]
000000H 400000H 600000H 800000H A00000H C00000H E00000H FFFFFFH
1st overflow 2nd overflow 3rd overflow 4th overflow
Offset = 0 V
Fine normalization= 100 %
Hexadecimal value
Fig. 7-10 Voltage range for test sockets
Shift factor
Voltage range
7 Fault Handling/Diagnostics